<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-25 08-23-29
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.2 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 61 kHz 3861 0,0777
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,2 dBr 4,24 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 61 kHz MIN: 13 kHz % above 76 kHz: 0,0777 Acquired: 2024/12/25 8.22.25 Total samples: 3861 Equivalent time: 0:03:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 5,8 dBr MIN: 2,2 dBr AVE: 4,24 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2024/12/25 8.22.25) 08.08 08.10 08.12 08.14 08.16 08.18 08.20 08.22 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]